Riken SD-1Series Explosion-proof Gas DetectorSD-1Series Explosion-proof Gas Detector

specification:
Usable even in hazardous atmospheres with hydrogen and acetylene present!

  • ATEX / IECEx certificate
  • Flameproof enclosure for Acetylene and Hydrogen
  • Self diagnosis by microprocessor

Contact window: sales@scientek-co.com

DESCRIPTION

【Model List】
Model Principle of detection Sampling method
SD-1(GP) Catalytic Combustion Method Diffusion
SD-1(NC) New Ceramic catalytic Method Diffusion
SD-1RI Non-dispersive infrared type Diffusion


Details:
Type Fixed Intelligent Detector
Detector gas type Volatile organic compound gases
Principle of detection Catalytic Combustion Method, New Ceramic catalytic Method
Detection range TYPE GP : 0 to 100%LEL
TYPE NC : Depends on detection target gas
Alarm setpoints TYPE GP : 25%LEL
TYPE NC : Depends on detection target gas.
Sampling method Suction and Diffusion
Type of alarm Gas alarm / fault alarm
Display of alarm Lamp lighting / information displayed
Explosion protected construction Flameproof enclosures
Ingress proof rating IP65
Explosion-proof class IECEx : Ex db ⅡC T5 Gb
ATEX : Ⅱ 2G Ex db ⅡC T5 Gb
Approvals Japan Ex, ATEX, IECEx, Brazil Ex, Taiwan Ex, China Ex, MED
CE marking EMC / ATEX / RoHS
Power source 24 VDC±10 %
Weight/Dimensions   Approx. 2.0 kg [SD-1]
Approx. 約148(W)×161(H)×88(D)mm (projection portions excluded)
Operating temperature/humidity range -20 to +60℃ (no sudden changes)
0 to 95 %RH (no condensation)